Construction
Solid bare copper conductors insulated with thermoplastics polyolefin. Two insulated conductors twisted together. Four such pairs separated by cross filler. The outer jacket is made with PVC, LSZH, PE compound.
Standard Compliances
ISO/IEC 11801:2011(Ed.2.2)
IEC 61156-5:2009(Ed.2.0)
EN 50173-1:2011
EN 50173-2:2007 including amendment A1:2010
ANSI/TIA-568-C.2:2009
Applications
IEEE 802.3: 1000BASE-T (Gigabit Ethernet), 100BASE-TX, 10BASE-T
ANSI/TIA/EIA-854: 1000BASE-TX
155 Mb/s, 1.2 Gb/s ATM
ANSI X3.263: 100 Mb/s
IEEE 802.3af DTE Power (POE)
4/16 Mb/s Token Ring
Digital Video
Broadband and Baseband Analog Video
Cable Description
Conductor |
Size |
23AWG |
Type |
Solid bare copper |
Diameter (mm) |
0.55± 0.01 |
Insulation |
Type |
PE |
Diameter (mm) |
0.973± 0.05 |
Min. thickness (mm) |
0.186 |
Pairs with color code |
Pair 1 |
Blue / White – blue strip |
Pair 2 |
Orange / White – orange strip |
Pair 3 |
Green / White – green strip |
Pair 4 |
Brown / White – brown strip |
Central Element |
Type |
PE cross separator |
Jacket |
Type |
PVC, LSZH, PE |
Overall Diameter (mm) |
6.1 ± 0.3 |
Technical data- Physical
Cold bend test |
-20 ± 2℃ X 4hrs no. crack |
Dielectric strength |
AC 1.7 KV for 2S. |
Insulation |
Before Aging |
After aging |
Min. Tension strength (psi) |
2400 |
75% before aging (100℃ X 48hrs) |
Min elongation (%) |
300 |
75% before aging (100℃ X 48hrs) |
Jacket |
Min. Tension strength (psi) |
2000 |
75% before aging (100℃ X 168hrs) |
Min elongation (%) |
100 |
50% before aging (100℃ X 168hrs) |
Min. bending radius (mm) |
50 |
Max. pulling tension (Ibs) |
25 |
Installation temperature |
-10℃ to +60℃ |
Operating temperature |
-10℃ to +60℃ |
|
|
|
|
|
Technical data- Electrical
Conductor resistance (Ω/100m @ 20℃) |
Max. |
9.5 |
DC resistance unbalance (%) |
Max. |
4 |
Pair-to-ground capacitance unbalance (pF/km) |
Max. |
1600 |
Delay skew (ns/100m) |
Max. |
45 |
4 ≦ f ≦ 250MHz |
Insertion Loss (dB/100m) |
Max. |
1.82*√f + 0.0169* f +0.25/√f |
1 ≦ f ≦ 250MHz |
Pair to Pair NEXT (dB/100m) |
Min. |
75.3 – 15 * log(f) |
1 ≦ f ≦ 250MHz |
PowerSum pr-pr NEXT (dB/100m) |
Min. |
72.3 – 15 * log(f) |
1 ≦ f ≦ 250MHz |
ELFEXT (dB/100m) |
Min. |
68 – 20 * log(f) |
1 ≦ f ≦ 250MHz |
PowerSum ELFEXT (dB/100m) |
Min. |
65 – 20 * log(f) |
1 ≦ f ≦ 250MHz |
Return Loss (dB) |
Min. |
20 + 5 * log(f) |
1 ≦ f <10MHz |
|
|
25 |
10 ≦ f <20MHz |
|
|
25 – 7 * log(f / 20) |
20 ≦ f ≦250MHz |
Propagation Delay (ns/100m) |
Max. |
534 + 36 /√f |
1 ≦ f ≦ 250MHz |
Input Impedance (Ω) |
|
100 ± 15% |
1 ≦ f ≦ 100MHz |
|
|
100 ± 22% |
100<f≦ 250MHz |
IEC 61156-5 ed2.0 Category 6 horizontal cable parameters |
Freq.
(MHz)
|
Ins. Loss
(dB/100m) |
RL
(dB) |
Pair to Pair |
Power Sum |
Po. Delay
(ns/100) |
NEXT |
ELFEXT |
NEXT |
ELFEXT |
(dB/100m) |
(dB/100m) |
|
Max. |
Min. |
Min. |
Min. |
Min. |
Min. |
Max. |
1 |
2.1 |
20 |
75.0 |
68.0 |
72.3 |
65.0 |
570.0 |
4 |
3.8 |
23 |
66.3 |
56.0 |
63.3 |
53.0 |
552.0 |
10 |
6.0 |
25 |
60.3 |
48.0 |
57.3 |
45.0 |
545.4 |
16 |
7.6 |
25 |
57.2 |
43.9 |
54.2 |
40.9 |
543.0 |
20 |
8.5 |
25 |
55.8 |
42.0 |
52.8 |
39.0 |
542.0 |
31.25 |
10.7 |
23.6 |
52.9 |
38.1 |
49.9 |
35.1 |
540.4 |
62.5 |
15.5 |
21.5 |
48.4 |
32.1 |
45.4 |
29.1 |
538.6 |
100 |
19.9 |
20.1 |
45.3 |
28.0 |
42.3 |
25.0 |
537.6 |
200 |
29.1 |
18 |
40.8 |
22.0 |
37.8 |
19.0 |
536.5 |
250 |
33.0 |
17.3 |
39.3 |
20.0 |
36.3 |
17.0 |
536.3 |
Note
All tests include 401 points swept frequency measurements.
All electrical characteristics are given at 20℃